• español
    • English
  • What is Séneca
  • How publish
  • Guidelines
  • Contact us
View Item 
  •   Séneca Home
  • Facultad de Ciencias
  • Departamento de Física
  • Física
  • Tesis/Trabajos de Grado
  • View Item
    • español
    • English
  •   Séneca Home
  • Facultad de Ciencias
  • Departamento de Física
  • Física
  • Tesis/Trabajos de Grado
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Browse

All of SénecaCommunities and CollectionsAuthorsTitlesThemeTypes of contentsAuthor profiles
This CollectionFaculties and ProgramsAuthorsTitlesThemeTypes of contents

My Account

LoginRegister

Statistics

View Usage Statistics

Estudio computacional de un detector GEM para la producción de imágenes de rayos X

RISMendeley
http://hdl.handle.net/1992/53638

  • Tesis/Trabajos de Grado [418]

Barreto Neira, Carlos Alberto
Avila Bernal, Carlos Arturo
2021
Trabajo de grado - Pregrado
Radiación - Mediciones
Detectores de gas
En este trabajo se realizó un estudio computacional de un detector de radiación GEM con el objetivo de evaluar su desempeño para la obtención de imágenes de rayos X. Como criterios de evaluación de desempeño se usaron la ganancia de carga y la resolución de energía. Una ganancia alta y una buena resolución implican que las imágenes que se puedan obtener tendrán una buena relación señal a ruido. Para realizar este estudio, se definió una geometría de tres láminas GEM con el programa GMSH, se calculó el campo eléctrico con el programa ELMER y se simuló la detección de radiación y el transporte de carga con el programa Garfield++. Los resultados de las simulaciones permitieron verificar que se puede obtener ganancias por encima de 10^4 aplicando voltajes de 400 V en cada una de las tres láminas GEM. Además, se encontró que la resolución de energía del detector simulado es 19,7%, lo cual está de acuerdo con las simulaciones y mediciones reportadas en la literatura.
 
In this work, a computational study of a GEM radiation detector was carried out with the objective of evaluating the performance of the detector for obtaining X-ray images. As performance evaluation criteria, the charge gain and energy resolution were used. High gain and good resolution mean that the obtainable images will have a good signal-to-noise ratio. To carry out this study, a geometry of three GEM sheets was defined with the GMSH program, the electric field was calculated with the ELMER program, and radiation detection and charge transport were simulated with the Garfield++ program. The results of the simulations allowed to verify that gains above 10^4 can be obtained by applying voltages of 400 V in each of the three GEM lines. Furthermore, it was found that the energy resolution of the simulated detector is 19.7%, which is in agreement with the simulations and measurements reported in the literature.
 
View Usage Statistics
Show full item record

Portada

Thumbnail

Name: 24633.pdf

[PDF] PDF Open Access[PDF] VER Open Access

Cita

Cómo citar

Cómo citar

Código QR


Carrera 1 # 18A-12

Bogotá - Colombia

Postal Code: 111711

+57 1 3394949 Ext.3322

biblioteca@uniandes.edu.co

Donaciones

Los Andes

Donaciones


Icono Repositorio

Los Andes

Repositorio


Icono Egresados

Los Andes

Egresados


Icono Eventos

Los Andes

Eventos



Redes sociales

  • Facebook
  • twitter
  • youtube
  • instagram
  • whatsapp

Universidad de los Andes | Vigilada Mineducación

Reconocimiento como Universidad: Decreto 1297 del 30 de mayo de 1964.

Reconocimiento personería jurídica: Resolución 28 del 23 de febrero de 1949 Minjusticia.

© - Derechos Reservados Universidad de los Andes